20 public reference projects

A crawlable microgrid benchmark catalog

Inputs, starting system sizes, climate labels, fuel assumptions, and computed outputs—from an 8 kW arctic telecom relay to a 2 MW island feeder.

Reference inputs and baseline designs

Every row is server-rendered as readable text and available as machine-readable JSON. Annual load and outputs are recomputed from the same deterministic engine on every build.

Benchmark boundary. These are synthetic reference cases for regression testing, education, and first-pass comparisons—not measured project data. The sizes shown are deterministic starting designs, not optimizer recommendations. Open a case and run the sizing search before comparing candidates.
Public MicrogridModeler benchmark inputs and starting designs
Reference projectPeak loadAnnual loadClimate / coordinatesFuelStarting PVStarting batteryStarting genset
telecom8 kW52,847 kWharctic68.4°, 18.0°$1.60/L100 kW20 kWh10 kW
telecom12 kW81,095 kWhdesert24.5°, 54.4°$1.30/L50 kW50 kWh15 kW
clinic20 kW97,887 kWhtropical5.6°, -0.2°$1.45/L50 kW50 kWh30 kW
clinic60 kW287,613 kWhtemperate30.1°, 31.2°$1.30/L200 kW200 kWh70 kW
hospitality80 kW371,692 kWhtropical10.5°, 72.6°$1.55/L200 kW200 kWh100 kW
hospitality300 kW1,379,144 kWhtropical12.2°, 96.9°$1.55/L1.00 MW1,000 kWh400 kW
school40 kW135,421 kWhcontinental41.0°, 74.0°$1.20/L100 kW100 kWh50 kW
school120 kW396,911 kWhtemperate35.2°, -82.5°$1.20/L200 kW500 kWh150 kW
village50 kW171,415 kWhtropical8.5°, 38.0°$1.45/L100 kW200 kWh70 kW
village150 kW512,288 kWhtropical-2.3°, 34.7°$1.45/L500 kW500 kWh200 kW
village400 kW1,341,879 kWhtropical6.4°, 3.4°$1.50/L1.00 MW1,000 kWh500 kW
mine-camp250 kW1,555,983 kWhdesert22.0°, 15.0°$1.40/L1.00 MW500 kWh300 kW
mine-camp1.00 MW6,323,839 kWhcontinental60.0°, 110.0°$1.70/L10.00 MW2,000 kWh1.50 MW
cold-storage150 kW824,557 kWhtemperate33.0°, -5.0°$1.30/L500 kW500 kWh200 kW
water-pumping75 kW232,676 kWhdesert28.0°, 70.0°$1.30/L100 kW200 kWh100 kW
cold-storage200 kW1,116,745 kWhmaritime45.0°, -60.0°$1.45/L1.00 MW500 kWh300 kW
utility-feeder500 kW2,448,879 kWhtemperate45.0°, 7.0°$1.35/L2.00 MW2,000 kWh700 kW
mine-camp300 kW1,897,883 kWhdesert25.0°, 51.0°$1.40/L1.00 MW1,000 kWh400 kW
military750 kW4,815,830 kWhdesert31.0°, 65.0°$1.60/L2.00 MW2,000 kWh1.00 MW
utility-feeder2.00 MW9,181,490 kWhtropical15.0°, 145.7°$1.85/L5.00 MW5,000 kWh3.00 MW

Computed baseline results

Use these values as transparent regression anchors. They are not independent validation against another engine.

arctic8 kW

Arctic telecom relay

Extreme cold, highly stable 24/7 load, scarce winter sun.

Renewable
43%
LCOE
$0.667
NPC saved
22%
Open in Modeler →
desert12 kW

Desert telecom relay

High irradiance, battery thermal stress.

Renewable
57%
LCOE
$0.381
NPC saved
46%
Open in Modeler →
tropical20 kW

Remote clinic (small)

Refrigeration-critical vaccine cold chain.

Renewable
54%
LCOE
$0.450
NPC saved
49%
Open in Modeler →
temperate60 kW

Remote clinic (medium)

Nighttime reliability emphasis.

Renewable
62%
LCOE
$0.365
NPC saved
55%
Open in Modeler →
tropical80 kW

Island guesthouse

Solar-rich, diesel backup.

Renewable
46%
LCOE
$0.507
NPC saved
47%
Open in Modeler →
tropical300 kW

Island resort

Strong daily cycling.

Renewable
59%
LCOE
$0.427
NPC saved
55%
Open in Modeler →
continental40 kW

Rural school

Weekday-dominant load.

Renewable
71%
LCOE
$0.314
NPC saved
66%
Open in Modeler →
temperate120 kW

Boarding school

Evening peaks, residential dorms.

Renewable
53%
LCOE
$0.418
NPC saved
56%
Open in Modeler →
tropical50 kW

Village microgrid (tiny)

Load-growth sensitivity.

Renewable
54%
LCOE
$0.464
NPC saved
56%
Open in Modeler →
tropical150 kW

Village microgrid (small)

Productive-load uncertainty.

Renewable
56%
LCOE
$0.455
NPC saved
57%
Open in Modeler →
tropical400 kW

Village microgrid (medium)

Generator sizing sensitivity (single aggregate genset modeled).

Renewable
55%
LCOE
$0.446
NPC saved
59%
Open in Modeler →
desert250 kW

Mine camp (small)

High diesel displacement value.

Renewable
50%
LCOE
$0.434
NPC saved
43%
Open in Modeler →
continental1.00 MW

Mine camp (medium)

Strong redundancy requirement.

Renewable
48%
LCOE
$0.616
NPC saved
31%
Open in Modeler →
temperate150 kW

Cold storage agro site

Strong refrigeration base load.

Renewable
46%
LCOE
$0.455
NPC saved
40%
Open in Modeler →
desert75 kW

Water pumping station

Dispatchable daytime pumping.

Renewable
64%
LCOE
$0.354
NPC saved
66%
Open in Modeler →
maritime200 kW

Fisheries / ice plant

High morning/evening peaks, ice making.

Renewable
46%
LCOE
$0.520
NPC saved
37%
Open in Modeler →
temperate500 kW

Remote municipality

Mixed critical / non-critical loads.

Renewable
56%
LCOE
$0.421
NPC saved
49%
Open in Modeler →
desert300 kW

Construction camp

Short project horizon, temporary site.

Renewable
48%
LCOE
$0.446
NPC saved
41%
Open in Modeler →
desert750 kW

Remote military support base

Reliability and fuel resilience priority.

Renewable
48%
LCOE
$0.478
NPC saved
43%
Open in Modeler →
tropical2.00 MW

High-fuel-cost island feeder

High fuel-scarcity cost (multi-generator staging is a roadmap item).

Renewable
50%
LCOE
$0.556
NPC saved
50%
Open in Modeler →

Metrics shown are for the starting hybrid design under the published synthetic assumptions. Open any project and run the optimizer to search the sampled design space.